Missing needle during episiotomy repair

Roychowdhury, Joydeb and Samanta, Balaram (2008) Missing needle during episiotomy repair. Online Journal of Health and Allied Sciences, 6 (3). ISSN 0972-5997

Full text available as:

PDF - Requires Adobe Acrobat Reader or other PDF viewer.
171 Kb

Official URL: http://www.ojhas.org/issue23/2007-3-4.htm

Abstract

Breakage and missing of the episiotomy needle is not uncommon occurrence at the hands of the junior doctors. Retrieving it from deeper tissue planes following its migration can be a challenging task.

EPrint Type:Article
Uncontrolled Keywords:Episiotomy, Needle, Migration, Tissues
Subjects:-Journal Repositories > Online Journal of Health and Allied Sciences
Equipment and Supplies > Needles
Surgical Procedures, Operative > Obstetric Surgical Procedures > Delivery, Obstetric
Surgical Procedures, Operative > Obstetric Surgical Procedures
ID Code:2565
Deposited By:Dr Srinivas Kakkilaya
Deposited On:15 February 2008

Archive Staff Only: edit this record