Missing broken needle during caesarean section.
Online Journal of Health andAllied Sciences, 8 (2).
ISSN 0972-5997
Full text available as: Official URL: http://www.ojhas.org/issue30/2009-2-12.htm AbstractBreakage of the needle and missing while repairing the uterine wound during cesarean section is an uncommon event. Subsequently it was removed under fluoroscopic guidance on the 7th postoperative day. | EPrint Type: | Article |
|---|
| Uncontrolled Keywords: | Broken Needle, Foreign body, Caesarean section, Uterine Wound, Surgery |
|---|
| Subjects: | Surgical Procedures, Operative > Urogenital Surgical Procedures Surgical Procedures, Operative > Laparotomy Surgical Procedures, Operative > Postoperative Period -Journal Repositories > Online Journal of Health and Allied Sciences Equipment and Supplies > Needles Surgical Procedures, Operative > Obstetric Surgical Procedures > Delivery, Obstetric Surgical Procedures, Operative > Device Removal |
|---|
| ID Code: | 3427 |
|---|
| Deposited By: | Dr Srinivas Kakkilaya |
|---|
| Deposited On: | 03 November 2009 |
|---|
Archive Staff Only: edit this record |